Library
PubMed
research article
Professional

Non-invasive somatotopic proprioceptive feedback for closed-loop robotic hand aperture control.

Source: PubMed, NCBI / U.S. National Library of Medicine

Journal of neural engineeringLecompte Olivier, Achiche Sofiane, Haddad Maria, et al.Published 5/26/2026Last synced 5/28/2026Status: syncedPMID: 42127983DOI: 10.1088/1741-2552/ae6d76

Current robotic prostheses developed for individuals with transradial amputation often lack physiological feedback, particularly proprioceptive information, which limits control precision and increases reliance on vision.This study investigates the effect of introducing non-invasive somatotopic feedback using transcutaneous electrical nerve stimulation (TENS) to convey hand aperture information, as an artificial form of proprioceptive feedback. Twenty healthy participants with intact limbs were divided into two groups: one receiving TENS-based feedback and one without feedback. Participants performed an aperture control task under visual and non-visual conditions, with some trials including a concurrent Stroop task to assess cognitive load. We hypothesized that providing non-invasive somatotopic proprioceptive feedback via TENS mitigates key control and integration challenges, leading to improved accuracy, faster learning, and reduced reliance on vision, without increasing cognitive demands.Under visual deprivation, participants receiving TENS feedback achieved significantly smaller aperture control errors than those without feedback, both under alternating visual conditions (p<0.001) and under prolonged visual deprivation conditions (p=0.017). From the very first trial, TENS-based feedback enabled control accuracy comparable to that with visual input. Although perceptual shifts affected control accuracy under dual-task conditions, the +TENS group maintained high cognitive pe

Abstract

Current robotic prostheses developed for individuals with transradial amputation often lack physiological feedback, particularly proprioceptive information, which limits control precision and increases reliance on vision.This study investigates the effect of introducing non-invasive somatotopic feedback using transcutaneous electrical nerve stimulation (TENS) to convey hand aperture information, as an artificial form of proprioceptive feedback. Twenty healthy participants with intact limbs were divided into two groups: one receiving TENS-based feedback and one without feedback. Participants performed an aperture control task under visual and non-visual conditions, with some trials including a concurrent Stroop task to assess cognitive load. We hypothesized that providing non-invasive somatotopic proprioceptive feedback via TENS mitigates key control and integration challenges, leading to improved accuracy, faster learning, and reduced reliance on vision, without increasing cognitive demands.Under visual deprivation, participants receiving TENS feedback achieved significantly smaller aperture control errors than those without feedback, both under alternating visual conditions (p<0.001) and under prolonged visual deprivation conditions (p=0.017). From the very first trial, TENS-based feedback enabled control accuracy comparable to that with visual input. Although perceptual shifts affected control accuracy under dual-task conditions, the +TENS group maintained high cognitive performance and effective control toward perceived functional targets, suggesting that the artificial feedback nonetheless supported hand control in the presence of a secondary task.These findings highlight the potential of non-invasive somatotopic proprioceptive feedback delivered through TENS to provide physiologically meaningful information and support future strategies for restoring proprioceptive function in prosthetic hand users.

Educational only
This information is for general education and is not medical advice. Always talk to a licensed U.S. clinician about your situation, medications, or treatment decisions.