Library
PubMed
research article
Professional

Glucose-Derived Personalized HbA1c Correction (GDAC) Study to Improve Alignment Between CGM-Derived Metrics and HbA1c in Different Individuals and Racial Groups With Diabetes: Implications for Clinical Practice.

Source: PubMed, NCBI / U.S. National Library of Medicine

Diabetes careAjjan Ramzi A, Choudhary Pratik, Xu Yongjin, et al.Published 6/8/2026Last synced 6/12/2026Status: syncedPMID: 42257619DOI: 10.2337/dc26-0398

Glycated hemoglobin (HbA1c) and average glucose (AG) can show discordance due to personal variations in red blood cell (RBC) physiology, creating management difficulties. Our aims were to understand the size of the problem and refine this glycemic metric by adjusting for personal differences in RBC characteristics. A 26-week prospective study was conducted in individuals with type 1 diabetes (T1D) or type 2 diabetes across four racial groups with HbA1c collected every 2 weeks and continuous glucose monitoring (CGM) used throughout. Personal glycation ratio (PGR) was derived from HbA1c and AG data (weeks 0-12), allowing calculation of personalized HbA1c (pA1C) and subsequent testing (weeks 20-26). The relationship between AG and HbA1c or pA1C was then analyzed, documenting a clinically meaningful discordance of ≥0.5%. In addition, we used real-world data sets to further validate the accuracy of pA1C at reflecting glucose exposure. Of 257 participants (19% T1D) with complete CGM and HbA1c data sets, mean age (±SD) was 53 ± 14 years (45% females). The racial background was 35% Asian, 30% White, 22% Black, and 14% other/mixed. Of the total study population, 33% showed ≥0.5% HbA1c-AG discordance, with the Black population affected most (41% discordance). Use of pA1C reduced the discordance in the whole population to 14% (58% reduction), while this was reduced in the Black population to 12% (71% reduction). HbA1c-AG discordance is common, particularly in the

Abstract

Glycated hemoglobin (HbA1c) and average glucose (AG) can show discordance due to personal variations in red blood cell (RBC) physiology, creating management difficulties. Our aims were to understand the size of the problem and refine this glycemic metric by adjusting for personal differences in RBC characteristics. A 26-week prospective study was conducted in individuals with type 1 diabetes (T1D) or type 2 diabetes across four racial groups with HbA1c collected every 2 weeks and continuous glucose monitoring (CGM) used throughout. Personal glycation ratio (PGR) was derived from HbA1c and AG data (weeks 0-12), allowing calculation of personalized HbA1c (pA1C) and subsequent testing (weeks 20-26). The relationship between AG and HbA1c or pA1C was then analyzed, documenting a clinically meaningful discordance of ≥0.5%. In addition, we used real-world data sets to further validate the accuracy of pA1C at reflecting glucose exposure. Of 257 participants (19% T1D) with complete CGM and HbA1c data sets, mean age (±SD) was 53 ± 14 years (45% females). The racial background was 35% Asian, 30% White, 22% Black, and 14% other/mixed. Of the total study population, 33% showed ≥0.5% HbA1c-AG discordance, with the Black population affected most (41% discordance). Use of pA1C reduced the discordance in the whole population to 14% (58% reduction), while this was reduced in the Black population to 12% (71% reduction). HbA1c-AG discordance is common, particularly in the Black population, with pA1C improving alignment with glucose levels, potentially helping to optimize clinical management and reduce health disparities.

Educational only
This information is for general education and is not medical advice. Always talk to a licensed U.S. clinician about your situation, medications, or treatment decisions.