Library
PubMed Central Open Access
research article
Professional
Open access

Drill choice as a modifiable factor in pediatric sEEG safety

Source: PubMed Central Open Access, NCBI / U.S. National Library of Medicine

Child's Nervous SystemLast synced 6/23/2026Status: syncedPMID: 42323487 pmidDOI: 10.1007/s00381-026-07319-4

Purpose Stereoelectroencephalography (sEEG) procedures require drilling serial burr holes for electrode placement. Key drilling characteristics include haptic feedback, ease of use, and time-efficient burr hole creation. Orthopedic drill bits are often repurposed for sEEG. We present a case series highlighting sEEG as an application for a new-to-market neurosurgery-tailored drill. Methods We performed a retrospective chart review on patients who underwent sEEG at our institution from 2022–2023. Patients were grouped by type of drill, Phasor(a disposable battery-operated drill 3.20-mm diameter, 210-mm usable length) or Stryker(Orthopedic Drill Cordless). Results Twelve patients underwent sEEG with the neurosurgery-tailored drill (2 unilateral and 10 bilateral); on average 10.7 ± 1.6 electrodes were placed per patient and mean operative duration was 162.9 ± 49 min. Tactile feel of bony layers and consistent drill time per burr hole (< 15 s) was subjectively noted. No complications were noted. Five patients underwent sEEG with the Strykerorthopedic drill (2 unilateral and 3 bilateral); an average of 11 ± 2.9 electrodes were placed per patient, mean operative duration was 176.4 ± 18.9 min. Subjectively, drill time per burr hole was variable and increased in duration between the first and final hole. One patient incurred a skin burn at the drill site which led to wound dehiscence and infection requiring prolonged wound care and antibiotics. Conclusion The Phasordrill offers a ligh

Abstract

Purpose Stereoelectroencephalography (sEEG) procedures require drilling serial burr holes for electrode placement. Key drilling characteristics include haptic feedback, ease of use, and time-efficient burr hole creation. Orthopedic drill bits are often repurposed for sEEG. We present a case series highlighting sEEG as an application for a new-to-market neurosurgery-tailored drill. Methods We performed a retrospective chart review on patients who underwent sEEG at our institution from 2022–2023. Patients were grouped by type of drill, Phasor(a disposable battery-operated drill 3.20-mm diameter, 210-mm usable length) or Stryker(Orthopedic Drill Cordless). Results Twelve patients underwent sEEG with the neurosurgery-tailored drill (2 unilateral and 10 bilateral); on average 10.7 ± 1.6 electrodes were placed per patient and mean operative duration was 162.9 ± 49 min. Tactile feel of bony layers and consistent drill time per burr hole (< 15 s) was subjectively noted. No complications were noted. Five patients underwent sEEG with the Strykerorthopedic drill (2 unilateral and 3 bilateral); an average of 11 ± 2.9 electrodes were placed per patient, mean operative duration was 176.4 ± 18.9 min. Subjectively, drill time per burr hole was variable and increased in duration between the first and final hole. One patient incurred a skin burn at the drill site which led to wound dehiscence and infection requiring prolonged wound care and antibiotics. Conclusion The Phasordrill offers a lightweight, reliable, consistent, safe and efficient option for sEEG burr hole creation and may be considered as an alternative to the Strykerorthopedic drill. Abs1

Educational only
This information is for general education and is not medical advice. Always talk to a licensed U.S. clinician about your situation, medications, or treatment decisions.